Specification
Open loop vector or V / Hz induction motor control | |
Open loop Rotor Flux Control for induction motors (RFC-A) |
Ambient Operating Temperature | Size 1 - 4: -20C to 40C (-4F to 104F) @ 3 kHz switching freq. | Operation to 60C (140F) with de-rating |
Cooling Method | Forced convection |
Humidity | 95 % non-condensing at 40 C (104 F) |
Storage Temperature | Size 1 - 4: -40C to 60C (-40F to 140F) 24 months Max. |
Altitude | De-rate the continuous output current by 1% for every 100 m (328 ft) above 1000 m (3,280 ft) to a maximum of 3000 m (9,840 ft) |
Vibration | Tested in accordance with IEC 60068-2-64 and IEC 60068-2-6 |
Mechanical Shock | Tested in accordance with IEC 60068-2-27 and IEC 60068-2-29 |
Enclosure Rating | IP20, NEMA 1 conduit kits available |
Electromagnetic Capability | IEC/ EN 61800-3 Immunity and Emissions |
RoHS | Complies with the Restriction of Hazardous Substances Directive (2011/65/EU) |
Voltage | 100 V models: 100 to 120 Vac 10% |
Phase | 1 and 3 (Model dependent) |
Maximum Supply Imbalance | 2% negative phase sequence, 3% voltage imbalance between phases |
Input Frequency | 45 to 66 Hz |
Input Displacement Power Factor | 0.97 |
Switching Frequency | Size 1 - 4: 0.667, 1, 2, 3, 4, 6, 8 12 & 16 kHz |
Output Frequency Range | 0 to 550 Hz |
Frequency Accuracy | 0.02% of full scale |
Frequency Resolution | 0.01 Hz |
Analog Input Resolution | Voltage mode: 11 bits (unipolar) Current mode: 11 bits |
Braking | Dynamic braking transistor included, requires external resistor |
DC Bus Undervoltage Trip | 100 V models: 175 Vdc |
DC Bus Overvoltage Trip | Frame sizes 1 - 4: |
Frame size 5 - 9: | |
Drive Overload Trip | Programmable: Default settings: 180% for 3s, 150% for 60s |
Instantaneous Overcurrent Trip | 220% of rated motor current |
Phase Loss Trip | DC bus ripple threshold exceeded |
Over-temperature Trip | Drive heatsink temperature exceeds 95C (203F) |
Short Circuit Trip | Protects against output phase-to-phase fault |
Ground Fault Trip | Protects against output phase-to-ground fault |
Motor Thermal Trip | Electronically protects the motor from overheating due to loading conditions |
|